GPU colocation in Columbus
19 data centers in Columbus, with the power, kW per rack and liquid cooling each operator publishes.
Columbus data centers
| Facility | City | Power | Max per rack | Liquid cooling | Source |
|---|---|---|---|---|---|
| CologixCOL5 | Lewis Center, OH | 25 MW | 100 kW5-100 kW per cabinet load design | Yes | Baxtel |
| CologixCOL1 | Columbus, OH | - | 64 kWup to 64 kW per cabinet, 90 kW with special racks, operator page | Not published | Cologix |
| CologixCOL2 | Columbus, OH | - | 64 kWup to 64 kW per cabinet, operator page | Not published | Cologix |
| CologixCOL3 | Columbus, OH | 20 MW | 5 kW5 kW per cabinet load design | Not published | Cologix |
| Vantage Data CentersOH1 (New Albany campus) | New Albany, OH | 192 MW | - | Not published | Vantage Data Centers |
| 5C Data CentersCMH01 | Columbus, OH | 75 MW | - | Not published | 5C Data Centers |
| STACK InfrastructureNAL01 campus (NAL01A, NAL01B) | New Albany, OH | 60 MW | - | Not published | STACK Infrastructure |
| CologixCOL4 | Columbus, OH | 50 MW | - | Not published | Converge Digest |
| CologixCOL7 (Johnstown campus) | Johnstown, OH | 36 MW | - | Yes | Cologix |
| EdgedEdged Columbus | New Albany, OH | 24 MW | -company-wide claim: up to 120+ kW per rack air, 400+ kW with liquid | Not published | Edged |
| CologixCOL8 (Johnstown campus) | Johnstown, OH | 21 MW | - | Yes | Cologix |
| CentersquareCMH1 | Lewis Center, OH | 8 MW | - | Not published | Centersquare |
| ExpedientLewis Center (CMH3) | Lewis Center, OH | 7.5 MW | - | Not published | Baxtel |
| ExpedientDublin | Dublin, OH | 4.8 MW | - | Not published | Expedient |
| DartPointsCMH01 | Dublin, OH | 0.3 MW | - | Not published | DartPoints |
| CogentColumbus 2 | Columbus, OH | - | - | Not published | Cogent |
| CogentColumbus Office and Data Center | Columbus, OH | - | - | Not published | Cogent |
| QTS Data CentersNew Albany 1 (DC1, DC2) | New Albany, OH | - | - | Not published | QTS Data Centers |
| QTS Data CentersNew Albany 2 (DC1, DC2) | New Albany, OH | - | - | Not published | QTS Data Centers |
Sorted by published density, the operator's own figure. Other metros: GPU colocation directory.
The Columbus market
Columbus is mostly hyperscale campuses. Of the multi-tenant sites, Cologix's COL4 and COL5 are the ones built for AI densities. COL5 is designed for 5-100 kW per cabinet with liquid cooling. Sources: Converge Digest.